Global-Writers Profile

# Procedure Expected Result

1

In DataStudio, connect to the Site Core using a Global-Writers profile.

Check the access to the model panels.

IO Model Access
KPI Model Access
Access Model Access
Server Model Access
ISA-95 Model Access

Access to these model panels is enabled:

  • I/O Model

  • KPI Model

  • ISA-95 Model

These model panels are empty:

  • Access Model

  • Server Model

2

In the I/O model, select objects at various levels below the System object.

Check the object properties panel.

Object properties

The user has access to all objects in the I/O Model below the System object and their properties.

3

Select the System object.

Check the object properties panel.

Object properties - Access Denied

"Access is denied" is shown in the Object Properties panel.

4

Repeat step 2 with the KPI and ISA-95 Models.

The user has access to all objects and their properties.

5

View the audit trail.

Audit Trail - Denied

This error is shown: "The user doesn’t have permission to view Audit Trail."

6

Write a value to an I/O Action Item.

Write successful

"Write operation successful" is shown, and the value is written successfully, without an access permission error.